收藏我们   ENGLISH  
论文查询
范围:  
提 交
《化学分析计量》 2016年第06期
DOI:10.3969/j.issn.1008-6145.2016.06.012
HPLC-ELSD法测定三乙醇胺单、双、三酯季铵盐的含量
杨肖,孙清,孙玲,石海英
山东省药学科学院,山东省化学药物重点实验室,济南 250101 
Determination of Triethanolamine Monoester, Diester and Triester Ammonium Salt by HPLC-ELSD
杨肖,孙清,孙玲,石海英
Shandong Provincial Key Laboratory of Chemical Drug, Shandong Academy of Pharmaceutical Sciences, Jinan 250101, China 
摘要:建立正相高效液相色谱-蒸发光散射检测法测定工业样品中的三乙醇胺单、双、三酯季铵盐的含量。以正己烷-甲醇-四氢呋喃(体积比85∶10∶5,加0.5 mL三氟乙酸调节至pH 3.50)为流动相,等度洗脱三乙醇胺单、双、三酯季铵盐,色谱柱为HP-氨基正相柱,柱温27℃,流量1.0 mL/min,蒸发光散射检测器漂移管温度80℃,载气流量2.6 L/min。三乙醇胺单、双、三季铵盐质量浓度的自然对数与各自对应的色谱峰面积和的自然对数呈良好的线性,相关系数(r2)分别为0.9914,0.9967,0.9915。测定结果的相对标准偏差为0.6%~2.6%(n=6),加标回收率分别为98.6%,101.2%,97.9%。该方法准确快速,可以为三乙醇胺单、双、三酯季铵盐的生产工艺优化提供理论数据 
Abstract:A method for the determination of triethanolamine monoester, diester and triester ammonium salt by NP-HPLC-ELSD was established. Mobile phase was hexane-methanol-tetrahydrofuran (85∶10∶5, pH was adjusted to 3.50 by adding 0.05 mL trifluoroacetic acid). Chromatographic column was HP-Amino positive phase column, the column temperature was 27℃, the flow rate was 1.0 mL/min, evaporative light-scattering detector drift tube temperature was 80℃, and carrier gas flow rate was 2.6 L/min. Natural logarithm of mass concentration of triethanolamine monoester, diester and triester ammonium salt was linear with the natural logarithm of there chromatographic peak area, the relative coefficient (r2) were 0.9914, 0.9967, 0.9915, repectively. The relative standard deviation of detection results was 0.6%-2.6%(n=6), and addition recoveries were 98.6%, 101.2%, 97.9%, respectively. The method is fast and accurate, it can provide theoretical data for the optimization of production technology of triethanolamine monoester, diester and triester ammonium salt. 
关键词:高效液相色谱法;蒸发光散射检测器;三乙醇胺单、双、三脂季铵盐 
Keywords:high performance liquid chromatography; evaporation light scattering detector; triethanolamine monoester, diester and triester ammonium salt 
本文引用格式:
杨肖,孙清,孙玲,等.HPLC-ELSD法测定三乙醇胺单、双、三酯季铵盐的含量[J].化学分析计量,2016,25(6):51-54.
YANG X,SUN Q,SUN L,et al.Determination of Triethanolamine Monoester,Diester and Triester Ammonium Salt by HPLC-ELSD[J]. Chemical analysis and meterage,2016,25(6):51-54. 

全文:
相似文章:
  电喷雾检测器高效液相色谱法测定复方北豆根氨酚那敏片中灰毡毛忍冬皂苷乙和川续断皂苷乙
2024年第01期
  高效液相色谱法同时测定明胶空心胶囊中苯甲酸和山梨酸
2024年第01期
  高效液相色谱法测定化妆品原料中N-乙酰神经氨酸
2024年第01期
  高效液相色谱法测定诃子中诃黎勒酸和诃子酸
2024年第01期
  多功能针式过滤器净化超高效液相色谱法测定大米和花生中玉米赤霉烯酮
2024年第01期
  柱前衍生-高效液相色谱法测定脑蛋白水解物中多肽含量
2023年第11期
  高效液相色谱法测定化妆品中5种水杨酸酯紫外吸收剂
2023年第11期
  高效液相色谱法测定喘舒片中的硫及其结果的聚类分析
2023年第11期
  限进介质色谱柱高效液相色谱法测定动物源性食品中对乙酰氨基酚残留量
2023年第11期
  高效液相色谱法测定冷面、米线中乙二胺四乙酸二钠
2023年第10期
《化学分析计量》杂志社 版权所有,未经授权禁止复制或者建立镜像
地址:山东省济南市天桥区田庄东路3号 邮编:250031
电话:0531-85878132 85878224 85878278
鲁ICP备05018524号-6