石墨炉原子吸收分光光度法测定水中钛
杜青,任兰
南京市环境监测中心站,南京 210013 
Determination of Titanium in Water by Graphite Furnace Atomic Absorption Spectrophotometry
杜青,任兰
Nanjing Environmental Monitoring Centre, 210013 Nanjing, China 
摘要:建立石墨炉原子吸收分光光度法测定水中痕量可溶性钛和总钛。测量可溶性钛的样品通过0.45 μm水系微孔滤膜过滤后直接测定,测量总钛的样品根据不同类型采用硝酸、过氧化氢、硫酸的不同组合进行消解。通过试验确定了最佳石墨炉程序升温工作条件和热解涂层石墨管的应用。干扰试验表明水中常见共存离子不干扰钛的测定。本方法经6家实验室验证,在0~250 μg/L范围内线性良好,方法检出限可溶性钛为4.0 μg/L,总钛为7.0 μg/L。测定结果的相对标准偏差不大于12%(n=6),加标回收率为90.0%~107%,该方法对钛标准物质测定结果的相对误差为-3.4%~2.4%。该方法准确、可靠,检出限低,干扰少,易于推广应用。 
Abstract:The method for determination of soluble titanium and total titanium in water by graphite furnace atomic absorption spectrometry was established. Soluble titanium sample was filtered by 0.45 μm microporous membrane and total titanium sample was digested by different regent-nitric acid, hydrogen peroxide, sulfuric aicd and their combination according to different type of sample. The optimal measurement parameters and graphite tube available were developed through experiments. Co-existent element interference was undetected in normal samples. The method was verified by six laboratories, the linear range was 0-250 μg/L, the detection limit was 4.0 μg/L for soluted titanium and 7.0 μg/L for total titanium, the RSD of determination results was not more than 12%(n=6), and the recoveries ranged from 90.0% to 107%. The relative error of determination results of Ti standard material with this method ranged from-3.4% to 2.4%. This method is accurate and reliable with less interference and easy to be popularized and applied. 
关键词:水样;钛;石墨炉原子吸收分光光度法 
Keywords:water sample; titanium; graphite furnace atomic absorption spectrophotometry 
基金:国家环保部标准制修订项目(949) 
本文引用格式:
杜青,任兰.石墨炉原子吸收分光光度法测定水中钛[J].化学分析计量,2016,25(6):75-79.
DU Q,REN L.Determination of Titanium in Water by Graphite Furnace Atomic Absorption Spectrophotometry[J]. Chemical analysis and meterage,2016,25(6):75-79. 

全文:
相似文章:
  电感耦合等离子体质谱法同时测定地表水中10种元素
2022年第06期
  电感耦合等离子体发射光谱法测定钛合金中铝的质量控制图
2022年第01期
  二安替比林甲烷分光光度法测定预熔型精炼渣中的二氧化钛
2021年第11期
  高效液相色谱-电感耦合等离子体串联质谱法测定水样中6种硒形态
2021年第05期
  电感耦合等离子体质谱法检测农作物土壤中的镉、锡、锰、锑、钒、钛、锶金属污染物残留
2021年第01期
  电感耦合等离子体质谱法测定医用镍钛形状记忆合金中钴、铜、铬、铁、铌
2020年第06期
  悬浮固化液相微萃取高效液相色谱法测定环境水样中磺胺类药物
2020年第05期
  电感耦合等离子体原子发射光谱法测定钛合金中锆
2020年第02期
  电感耦合等离子体-原子发射光谱法同时测定铝合金中9 种元素
2020年第01期
  高频燃烧红外吸收光谱法测定钨钛合金中碳含量
2020年第01期
《化学分析计量》杂志社 版权所有,未经授权禁止复制或者建立镜像
地址:山东省济南市天桥区田庄东路3号 邮编:250031
电话:0531-85878132 85878224 85878278
鲁ICP备05018524号-6