摘要:采用电位滴定法测定铀铌合金溶解液中的铀,中子活化分析法测定不溶物中的铀。探讨了主要共存元素对电位滴定法测定结果的影响,其中当铌、钼、锆元素的质量分数分别为9.34%~42.14%、2.92%~22.72%、2.41%~7.80%时,测量相对偏差的绝对值为0.3%,对电位滴定测量结果的影响可以忽略。研究了中子活化法当滤纸不完全灰化时待测元素的损失情况,结果表明,灰化后样品的平均回收率为100.5%。采用电位滴定-中子活化法联合测定铀铌合金中铀,测定值的相对标准偏差为0.137%~0.993%(n=6),铀铌合金自制样品中铀含量测定值与理论值基本吻合。  
Abstract:Uranium in uranium niobium alloy solution was determined by potentiometric titration, and uranium in insoluble matter was determined by neutron activation analysis. The influence of main coexisting elements on the determination results of potentiometric titration was discussed. When the mass fraction of niobium, molybdenum and zirconium were 9.34%-42.14%, 2.92%-22.72% and 2.41%-7.80%, the absolute value of relative deviation was 0.3%, and the influence on the results of potentiometric titration can be ignored. The loss of elements to be measured when the filter paper was not completely ashed by neutron activation method was studied. The results show that the average recovery of the sample after ashing was 100.5%. The relative standard deviation of the determination value was 0.137%-0.993% (n=6). The measured value of uranium content in the self-made sample of uranium niobium alloy was basically consistent with the theoretical value.  
关键词:电位滴定法;中子活化法;铀铌合金;铀 
Keywords:potentiometric titration; neutron activation; uranium niobium alloy; uranium 
本文引用格式:
赵刚,丁丁,黄艳,等.电位滴定-中子活化法联合测定铀铌合金中铀[J].化学分析计量,2021,30(5):42.
Zhao Gang,Ding Ding,Huang Yan,et al. Determination of uranium in uranium niobium alloy by potentiometric titration and neutron activation method[J]. Chemical Analysis and Meterage,2021,30(5):42. 

全文:
相似文章:
  自动电位滴定法检测白酒中总酸的测量不确定度评定
2023年第08期
  吸收光谱法测定六价铀时5种杂质金属离子的干扰及消除
2023年第03期
  电位滴定法测定对甲基苯磺酸中硫酸
2023年第03期
  控制图核查分析系统在自动电位滴定法测定水泥中氯离子含量的应用
2022年第06期
  氧弹燃烧-自动电位滴定法测定助焊剂中的卤素
2022年第06期
  电感耦合等离子体光谱-质谱法联合测定铀化合物粉末中20种杂质元素
2022年第08期
  电感耦合等离子体质谱法测定空气中铀含量的不确定度评定
2022年第04期
  X射线荧光光谱法测定铀钼合金中钼
2022年第03期
  电位滴定法测定铜镁合金中镁
2022年第02期
  X射线荧光法测定天然铀产品中铀含量的不确定度评定
2022年第01期
《化学分析计量》杂志社 版权所有,未经授权禁止复制或者建立镜像
地址:山东省济南市天桥区田庄东路3号 邮编:250031
电话:0531-85878132 85878224 85878278
鲁ICP备05018524号-6