收藏我们   ENGLISH  
论文查询
范围:  
提 交
《化学分析计量》 2022年第06期
DOI:10.3969/j.issn.1008-6145.2022.06.005
高效液相色谱法测定水性涂料中碘丙炔醇丁基氨甲酸酯
甘合智,韦东,张海殷
广西壮族自治区产品质量检验研究院,南宁 530000 
Determination of 3-iodo-2-propynylbutylcarbamate in water-borne coating material by high performance liquid chromatography
GAN Hezhi, WEI Dong, ZHANG Haiyin
Guangxi Zhuang Autonomous Region Testing Institute of Product Quality, Nanning 530000, China 
摘要:建立高效液相色谱法测定水性涂料中生物杀伤剂碘丙炔醇丁基氨甲酸酯的分析方法。1.00 g水性涂料样品用约8 mL的甲醇超声提取10 min,冷却至室温后,用甲醇稀释至10.0 mL,以20 000 r/min转速离心5 min,上清液用0.22μm有机相滤膜过滤,采用高效液相色谱/二极管阵列检测器(HPLC/DAD)测定滤液中碘丙炔醇丁基氨甲酸酯的含量。以甲醇-0.05 mol/L磷酸二氢钾溶液(用磷酸调节pH至4.0±0.05)为流动相进行等度洗脱,采用Shim-pack GIST C色谱柱(250 mm×4.6 mm, 5μm)分离,检测波长为230 nm。碘丙炔醇丁基氨甲酸酯的质量浓 18 度在8.0~200.0μg/mL范围内与其对应的色谱峰面积线性关系良好,相关系数为0.999 9,检出限为43 mg/kg。样品加标回收率为87.5%~99.6%,测定结果的相对标准偏差为1.36%~2.98%(n=6)。 
Abstract:A method for determining biocide 3-iodo-2-propynylbutylcarbamate (IPBC) in water-borne coating material by high performance liquid chromatography was established. 1.00 g of water-borne coating material sample was extracted by ultrasonic for 10 min with about 8 mL methanol. After cooling to room temperature, the solution was diluted to 10.0 mL with methanol centrifugated for 5 min at the speed of 20 000 r/min, the supernatant was filtered with 0.22μm organic phase filter, and the content of 3-iodo-2-propynylbutylcarbamate in the filtrate was determined by high performance liquid chromatography/diode array detector (HPLC/DAD). Shim-pack GIST C chromatographic column (250 mm×4.6 18 mm, 5μm) was used for separation with methanol-0.05 mol/L potassium dihydrogen phosphate solution(adjusted the pH to 4.0±0.05 with phosphoric acid) as the mobile phase for isocratic elution. The detection wavelenth was 230 nm. The mass concentration of 3-iodo-2-propynylbutylcarbamate had a good linear relationship with its chromatographic peak area in the range of 8.0-200.0μg/mL, the correlation coefficient was 0.999 9, and the detection limit was 43 mg/kg. The recovery rate of standard addition was 87.5%-99.6%, and the relative standard deviation of determination results was 1.36%-2.98%(n=6). 
关键词:高效液相色谱法;水性涂料;生物杀伤剂;碘丙炔醇丁基氨甲酸酯 
Keywords:high performance liquid chromatography; water-borne coating material; biocide; 3-iodo-2-propynylbutylcarbamate 
本文引用格式:
甘合智,韦东,张海殷.高效液相色谱法测定水性涂料中碘丙炔醇丁基氨甲酸酯[J].化学分析计量,2022,31(6):18.
GAN Hezhi,WEI Dong,ZHANG Haiyin. Determination of 3-iodo-2-propynylbutylcarbamate in water-borne coating material by high performance liquid chromatography[J]. Chemical Analysis and Meterage,2022,31(6):18. 

全文:
论文未上传
相似文章:
  高效液相色谱法同时测定阿胶糕中16种防腐剂
2022年第06期
  高效液相色谱法测定杜仲壮骨丸中马兜铃酸A
2022年第06期
  高效液相色谱法测定药物涂层球囊中紫杉醇含量的不确定度评定
2022年第08期
  高效液相色谱法测定水产品中喹乙醇的不确定度评定
2022年第08期
  高效液相色谱法测定复方甘草口服溶液中8种防腐剂
2022年第07期
  高效液相色谱法测定奶粉中黄曲霉毒素M1的不确定度评定
2022年第07期
  高效液相色谱法测定小活络丸中葡萄糖、果糖、蔗糖、麦芽糖
2022年第05期
  高效液相色谱荧光法测定血液透析器中双酚A溶出量
2022年第05期
  高效液相色谱法测定茶枯粉中3种激素
2022年第05期
  高效液相色谱法测定牛黄解毒片中胆酸和猪去氧胆酸的含量及其质量分析
2022年第04期
《化学分析计量》杂志社 版权所有,未经授权禁止复制或者建立镜像
地址:山东省济南市天桥区田庄东路3号 邮编:250031
电话:0531-85878132 85878224 85878278
鲁ICP备05018524号-6