电感耦合等离子体发射光谱法测量防晒产品中氧化锌含量不确定度评定
李子宜,张春华
1. 广东省科学院测试分析研究所(中国广州分析测试中心),广东省化学测量与应急检测技术重点实验室,广州 510070; 2. 季华实验室,广东佛山 528000
Uncertainty evaluation for the determination of ZnO in sunscreen products by ICP-OES
LI Ziyi, ZHANG Chunhua12 1
1. Institute of Analysis, Guangdong Academy of Science (China National Analytical Center, Guangzhou
摘要:对电感耦合等离子体发射光谱法测定防晒产品中氧化锌含量的不确定度进行评定。测量不确定度主要来源于标准物质 、校准曲线 、溶液稀释和测量重复性。通过对各不确定度分量合成和扩展,当防晒霜中氧化锌含量为9.04% 时,其扩展不确定度 U=0.22%(k=2,置信区间为95%)。结果表明,标准物质 、标准曲线拟合、标准溶液配制与稀释及重复性测量对测定结果影响较大。
Abstract:Meaurenment uncertainty was evaluated of zinc oxide content in sunscreen products determined by inductively coupled plasma emission spectrometry. The uncertainty were mainly originate from the standard substance, calibration curve, dilution ratio and sample repeatability. By synthesizing and expanding the uncertainty components, when the content of zinc oxide in sunscreen is 9.04%, the expanding uncertainty U=0.22% (k=2, confidence interval was 95%). The results showed that the standard material, standard curve fitting, standard solution preparation and dilution also the repeatability measurement had great influence on the determination results.
关键词:测量不确定度;电感耦合等离子体发射光谱;氧化锌;防晒剂
Keywords:measurement uncertainty; inductively coupled plasma-optical emission spectrometer; zinc oxide;sunscreen
本文引用格式:
李子宜,张春华.电感耦合等离子体发射光谱法测量防晒产品中氧化锌含量不确定度评定[J].化学分析计量,2023,32(3):99.
LI Ziyi,ZHANG Chunhua. Uncertainty evaluation for the determination of ZnO in sunscreen products by ICP-OES[J]. ChemicalAnalysis and Meterage,2023,32(3):99.